C546 Elliptical Fitness Crosstrainerl
Page 31
interconnect cable is bad. Install a new interconnect cable per Procedure 7.7. If the unit
does not operate properly, continue with the next step.
10. Reconnect the original upper interconnect cable to the upper PCA.
Troubleshooting the Lower Interconnect Cable
11. Remove the shield from the lower PCA.
12. Remove the interconnect cable from the lower PCA.
13. Connect a known good lower interconnect cable between the lower PCA and the upper
interconnect cable.
14. Check operation as described in Section Four.
15. If the unit operated correctly when the spare lower interconnect cable was installed, the
original interconnect cable is bad. Install a new interconnect cable per Procedure 7.7. If the
unit does not operate properly, continue with the next step.
16. Reconnect the original lower interconnect cable to the lower PCA.
17. Reconnect the lower interconnect cable to the upper interconnect cable.
18. Replace the lower PCA shield.
19. Replace the rear cover.
20. Replace the interconnect cable cover.
21. Check operation as described in Section Four.
Version 1 units, manufactured after Feb. 7, 1999
22. Set the on/off switch in the “off” position.
23. Attach the anti-static wrist strap to your arm, then connect the ground lead of the wrist strap
to the units frame.
24. Remove the interconnect cable cover. (See Diagram 7.2)
25. Remove the rear cover.
26. Disconnect the interconnect cable from the upper PCA and from the lower PCA.
27. Connect a known good upper interconnect cable from the lower PCA to the upper PCA.
Route the cable outside of the unit at this time.
28. Check operation as described in Section Four.