Procedure 7.14 - Replacing the Eddy Current Disk Assembly
1. Current production of C546’s utilize an assembly that consists of the eddy current disk, input
pulley assembly and pillow block bearings. The pillow block bearings are permanently
attached to the input pulley shaft and can not be removed. If you encounter a situation
where the eddy current disk is damaged and requires replacement, the entire assembly
consisting of eddy current disk, input pulley and pillow block bearings must be replaced. See
Procedure 7.17 for replacement instructions.